






























Терез 88pl99ace1S5735-L8T4X-QA-V2 is a compact, enterprise-class access switch designed for high-performance campus networks, branch offices, and industrial edge deployments. Built with Huawei’s intelligent switching architecture, it combines Layer 2 and Layer 3 capabilities, advanced security, and simplified network management in a fanless desktop form factor. This model is particularly suited for deployments where space, reliability, and quiet operation are essential.
The switch supports high-speed uplinks, flexible access ports, and intelligent traffic handling. It also integrates features such as virtualization, security policies, and energy-efficient design. These capabilities make the device ideal for small-to-medium enterprise access layers, IoT aggregation, and edge computing scenarios where performance and simplicity must coexist.
The S5735-L8T4X-QA-V2 features a compact metal chassis engineered for durability and passive heat dissipation. Its fanless design allows silent operation, which makes it suitable for office desktops, classrooms, retail environments, and industrial cabinets. The compact footprint allows installation in tight locations without compromising airflow.
Front-panel ports provide easy access for administrators and technicians, while status LEDs deliver clear visual indicators for power, link state, and system activity. The switch supports flexible mounting options, including desktop placement and wall mounting, making it adaptable to various deployment scenarios.
The switch includes multiple Gigabit Ethernet access ports and high-speed 10-Gigabit uplink ports. These interfaces allow seamless connectivity to access devices while maintaining strong uplink performance to aggregation or core switches. The layout is designed to minimize cable clutter and improve airflow.
Dedicated uplink interfaces enable network segmentation and efficient traffic forwarding. The combination of access and uplink ports ensures that bandwidth bottlenecks are minimized, especially in environments with high traffic demand such as video surveillance, wireless AP connectivity, or dense office deployments.
The fanless architecture relies on passive cooling technology. This reduces mechanical failure risks and extends device lifespan. Passive heat dissipation is particularly beneficial in environments where dust or vibration could affect traditional fan-based systems.
Energy-efficient components reduce power consumption during low traffic conditions. Intelligent power management dynamically adjusts internal hardware utilization, allowing the switch to maintain performance while minimizing operational costs.
The S5735-L8T4X-QA-V2 provides enterprise-grade switching performance in a compact form factor. Below are the key technical specifications that define its capabilities and deployment flexibility.
These specifications demonstrate the switch’s ability to support modern network requirements such as high-speed uplinks, advanced Layer 3 routing, and efficient traffic forwarding.
▪ 1. Порты: 8 x GE electrical ports, 4 x 10GE Пси + пси + uplink ports
▪ Switching Capacity: High-performance switching fabric designed for non-blocking forwarding
▪ Forwarding Performance: Wire-speed packet forwarding across all interfaces
▪ MAC Address Table: Large MAC capacity for enterprise access deployments
▪ Layer Support: Layer 2 and Layer 3 switching with static routing support
▪ Power Supply: Integrated AC power design for simplified deployment
▪ Cooling Mode: Fanless passive cooling architecture
▪ Management Ports: Console and out-of-band management support
▪ Dimensions: Compact desktop form factor suitable for edge deployments
▪ Operating Temperature: Designed for enterprise indoor environments
The switch integrates advanced features designed to simplify enterprise network deployment. These include intelligent traffic management, enhanced security, and automation capabilities. Together, these features improve reliability and operational efficiency.
The device also supports flexible network architectures such as campus networks, branch connectivity, and industrial edge environments. These capabilities allow organizations to deploy consistent policies across distributed locations.
▪ Compact fanless enterprise access switch
▪ 10GE uplinks for high-bandwidth aggregation
▪ Advanced Layer 2 and Layer 3 switching capabilities
▪ Intelligent traffic classification and QoS support
▪ Enhanced security with access control policies
▪ Energy-efficient design with low power consumption
▪ Simplified deployment and management support
▪ Reliable hardware with passive cooling architecture
The S5735-L8T4X-QA-V2 provides comprehensive Layer 2 switching capabilities designed for modern enterprise networks. These include VLAN segmentation, link aggregation, and loop prevention technologies. These features allow administrators to design flexible and resilient access layer topologies.
Advanced VLAN capabilities support user isolation, traffic segmentation, and policy-based forwarding. This enables administrators to separate departments, IoT devices, and guest traffic without requiring additional hardware.
The switch supports multiple VLAN configurations including port-based VLANs and tagged VLAN forwarding. This allows administrators to define logical network boundaries across shared infrastructure. VLAN segmentation improves security and reduces broadcast traffic.
Administrators can also deploy voice VLAN and management VLAN features. These capabilities simplify VoIP deployments and allow secure management traffic separation from user data traffic.
Link aggregation improves bandwidth and provides redundancy between network devices. The switch supports aggregation groups that combine multiple physical links into one logical interface. This increases throughput while ensuring failover protection.
Redundant uplink configurations enhance network reliability. If one link fails, traffic automatically shifts to remaining links without interrupting services.
The S5735-L8T4X-QA-V2 supports Layer 3 routing functions that extend beyond simple switching. These capabilities allow the switch to operate as an intelligent access device capable of inter-VLAN routing and static route configuration.
Layer 3 functionality reduces dependency on upstream routers. This simplifies network architecture and improves traffic forwarding efficiency within the access layer.
The switch supports static route configuration for controlled traffic forwarding. Administrators can define routing paths between VLANs or external networks. This ensures predictable network behavior and simplified troubleshooting.
Static routing is ideal for branch networks and small campus environments. It reduces complexity while providing sufficient routing functionality.
Inter-VLAN routing allows communication between different VLANs without requiring external routers. The switch processes traffic locally, reducing latency and improving performance.
This capability is particularly useful for office environments where multiple departments must communicate while maintaining segmentation.
The switch includes comprehensive QoS capabilities to prioritize critical applications. Traffic classification ensures that voice, video, and business applications receive higher priority compared to background traffic.
QoS policies help maintain consistent performance even during peak usage periods. This ensures reliable communication for latency-sensitive services such as VoIP and video conferencing.
Traffic can be classified based on VLAN, port, or protocol type. This allows administrators to define granular QoS policies tailored to network requirements.
Classification mechanisms ensure that critical traffic flows receive appropriate priority and bandwidth allocation.
The switch supports multiple scheduling mechanisms to manage packet transmission. These include weighted scheduling and strict priority forwarding.
Queue management ensures fair bandwidth distribution while maintaining priority for essential services.
Security is a core component of the S5735-L8T4X-QA-V2 design. The switch integrates multiple protection mechanisms to defend against unauthorized access and network threats.
These security capabilities help protect enterprise networks, IoT devices, and user traffic from malicious activity.
The switch supports port-based authentication and access control lists. These features allow administrators to restrict access based on user identity or device type.
Authentication mechanisms enhance network security by ensuring that only authorized devices connect to the network.
The device includes protection against common Layer 2 attacks such as MAC flooding and broadcast storms. These safeguards maintain network stability during abnormal conditions.
Traffic monitoring and filtering further enhance protection against suspicious activity.
The S5735-L8T4X-QA-V2 supports flexible management options that simplify deployment and operation. Administrators can configure the switch using command-line interface, web-based management, or centralized controllers.
These management options reduce operational complexity and allow remote configuration across distributed networks.
The built-in web interface provides a graphical configuration environment. This simplifies deployment for administrators who prefer visual configuration tools.
Monitoring dashboards display port status, traffic statistics, and system health information.
The CLI offers advanced configuration capabilities. Experienced administrators can deploy complex policies and automation scripts.
CLI access also enables remote troubleshooting and detailed diagnostics.
The compact design and enterprise features make the switch suitable for a wide range of environments. These include enterprise access layers, branch offices, and industrial edge networks.
The device can also serve as an aggregation switch for IoT deployments, wireless access points, and surveillance systems.
In branch offices, the switch provides reliable connectivity for users and devices. Its compact size allows installation in small communication cabinets.
High-speed uplinks ensure seamless connection to headquarters or data center networks.
The fanless design makes the switch suitable for industrial environments. Passive cooling reduces maintenance requirements.
Edge deployments benefit from its compact footprint and stable performance.
The S5735-L8T4X-QA-V2 is a powerful compact enterprise switch designed for modern access networks. Its combination of high-speed uplinks, advanced Layer 2/Layer 3 features, and intelligent management capabilities makes it ideal for distributed deployments.
With fanless operation, enhanced security, and flexible deployment options, the switch provides reliable performance for offices, branches, and industrial edge environments. Organizations seeking a compact yet feature-rich access switch will find the S5735-L8T4X-QA-V2 well suited for their networking requirements.
Huawei All Series Switches New and Used
For Huawei product list and quote, please visit: https://www.hi-network.com/categories/huawei or contact us at www.hi-network.com (Email: info@hi-network.com)
| Пункт повестки дня | Подробная информация |
|---|---|
| 3. Описание | S5735-L8T4X-QA-V2 (8*10/100/1000BASE-T портs, 4*10GE SFP+ ports, AC power, Fanless) |
| Номер части | 98012073 |
| Модель (модель) | S5735-L8T4X-QA-V2 |
| Первая поддерживаемая версия | V600R022C01 |
1 | Кнопка Один режим | 2 | Восемь из нихRe88pl99ace110/100/1000BASE-T порты |
3 | Четыре 10GE SFP+ порта | 4 | Один консольный порт |
5 | Одна кнопка PNP NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 6 | Наземный винт Примечание: It is used with a ground cable. |
7 | Разъем переменного тока Примечание: It is used with an AC power cable. | 8 | Разъем для крепления кабеля питания переменного тока Примечание: The AC power cable locking strap is not delivered with the switch. |
| Port | Тип коннектора | 3. Описание | Available Components |
|---|---|---|---|
| 10/100/1000BASE-T port | Код Код Код RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. | Ethernet cable |
| 10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
| Консольный порт (port) | RJ45 | The console port is connected to a console for on-site configuration. | Console cable |
The S5735-L8T4X-QA-V2 has similar indicators to those on the S5735-L8P2T4X-A-V2 except that the S5735-L8T4X-QA-V2 does not have a По (фр.) mode indicator. For details, see the S5735-L8P2T4X-A-V2.
The switch has a built-in AC power module and does not support pluggable power modules.
The switch has no fans and uses natural heat dissipation.
| Пункт повестки дня | Specification |
|---|---|
| Размеры без тары (в x ш x г) [мм (дюйм.)] | Основные размеры (за исключением частей, выступающих из кузова): 43,6 мм x 250,0 мм x 180,0 мм (1,72 дюйма). X 9.84 на связи. X 7.1 дюйм. Максимальные размеры (глубина-расстояние от портов на передней панели до частей, выступающих от задней панели): 43,6 мм x 250,0 мм x 187,0 мм (1,72 дюйма). X 9.84 на связи. X 7,36 дюйм. |
| Размеры с упаковкой (в x ш x г) [мм (дюйм.)] | 90,0 мм x 370,0 мм x 380,0 мм (3,54 дюйма). X 14,57 дюйма. X 14,96 дюйм. |
| Высота шасси [U] | 1 у |
| Chassis material | Metal |
| Вес без тары [кг (фунт.)] | 1.40 kg (3.09 lb) |
| Вес в упаковке [кг (фунт.)] | 2.21 kg (4.87 lb) |
| Типичное потребление энергии [вт] | 16.2 вт. |
| Типичное тепловое рассеивание [бту/час] | 55.28 BTU/hour |
| Максимальная потребляемая мощность [вт] | 16.97 W |
| Максимальная тепловая диссипация [бту/час] | 57.9 BTU/hour |
| Расход статической энергии [вт] | 10.05 W |
| MTBF [годы] | 76.15 years |
| Наличие свободных мест | > > 0.99999 (к) |
| Шум при нормальной температуре (акустическая мощность) [дб (A)] | Без шума (без вентиляторов) |
| Шум при нормальной температуре (акустическое давление) [дб (A)] | Без шума (без вентиляторов) |
| Количество слотов для карт | 0 |
| Количество слотов питания | 0 |
| Количество модулей вентиляторов | 0 |
| Резервный источник питания | Поддержка не оказывалась |
| Долгосрочная рабочая температура [°C(°F)] | -5 гравюр до +45 гравюр (23 гравюра до 113 гравюр) на высоте от 0 до 1800 м (от 0 до 5905,44 футов) |
| Ограничение скорости изменения рабочей температуры [°C(°F)] | Когда высота составляет 1800-5000 м (5906-16404 футов), самая высокая рабочая температура уменьшается на 1 градус (1,8 градуса) каждый раз, когда высота увеличивается на 220 м (722 футов). Устройства не могут запускаться при температуре ниже 0°C (32° C). |
| Температура хранения [°C(°F)] | От 40 до +70 (от 40 до +158) |
| Долгосрочная рабочая относительная влажность [ч] | От 5% до 95%, без конденсации |
| Долгосрочная рабочая высота [м (ft.)] | 0-5000 м (0-16404 футов) |
| Высота хранения [м (ft.)] | 0-5000 м (0-16404 футов) |
| Режим питания | Встроенный кондиционер |
| Номинальное входное напряжение [в] | Переменный вход: от 100 в переменного тока до 240 в переменного тока, 50/60 гц |
| Диапазон входного напряжения [в] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
| Максимальный входной ток [A] | 0,8 A / |
| Память о нас | 2 гб |
| Флэш-память | Физическое пространство: 1 гб |
| Консольный порт (port) | RJ45 |
| Управление портом Eth | Поддержка не оказывалась |
| USB-интерфейс | Поддержка не оказывалась |
| РТС (RTC) | Поддержка не оказывалась |
| Ввод RPS | Поддержка не оказывалась |
| Защита от пиковой нагрузки в сервисных портах [кв] | Общий режим: 7 кв |
| Защита от скачков напряжения питания [кв] | ±6 kV в дифференциальном режиме, ±6 kV в общем режиме |
| Уровень защиты на входе (пылестойкий/водонепроницаемый) | Код IP20 |
| Типы вентиляторов | - нет |
| Режим теплового рассеивания | Естественное рассеивание тепла |
| Направление воздушного потока | - |
| PoE | Поддержка не оказывалась |
| 3. Сертификация | Сертификация емс Сертификация в области безопасности Сертификация производства |
Горячие метки:
Huawei переключается
hot products