Зарегистрируйтесь сейчас для лучшей персонализированной цитаты!

Новости по теме

Huawei S6730-S24X6Q: Advanced Ethernet Switch for Modern Networks

Jan, 23, 2025 Hi-network.com

s6730-s24x6q

The Huawei | S6730-S24X6Q is a high-performance Ethernet - переключатель designed to meet the demands of modern data centers and campus networks- да- да. It offers advanced features and robust specifications to ensure efficient and reliable network operations.

Key Features

▪ High Port Density: 24 x 10 Gigabit SFP+ ports and 6 x 40 Gigabit QSFP+ ports.
▪ High Switching Capacity: Up to 2.4 Tbit/s to handle heavy traffic loads.
▪ Advanced Layer 2 and Layer 3 Features: Supports comprehensive protocols for versatile network configurations.
▪ Stacking Capability: Supports stacking through 10GE SFP+ and 40GE QSFP+ ports for simplified management.
▪ Energy Efficiency: Designed for low power consumption to reduce operational costs.
▪ Comprehensive Security: Без учета стоимостиers features like ACLs, 802.1X authentication, and DHCP snooping for enhanced network protection.
▪ Качество обслуживания (QoS(1): Provides traffic classification and prioritization to ensure optimal performance for critical applications.
▪ Flexible Management: Supports various management methods, including CLI, web-based management, and SNMP.
▪ High Reliability: Features redundant power supplies and hot-swappable fan modules for continuous operation.
▪ Virtual Extensible LAN (VXLAN): Supports VXLAN L2 and L3 gateways for network virtualization.

Технические характеристики

Ports: 24 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports.
Switching Capacity: 2.4 Tbit/s.
Forwarding Performance: 480 Mpps.
Размеры (в x ш x г): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.).
Вес (с упаковкой): 8,9 кг (19,62 фунтов).
Power Supply: Supports dual AC and DC power modules.
Operating Temperature: -5 - гравюра до +45 - гравюра (23-113 - гравюра) на высоте 0-1800 м (0-5906 футов).
Operating Humidity: От 5% до 95%, без конденсации.
Stacking Support: Up to 16 physical ports for stacking using 10GE SFP+ and 40GE QSFP+ ports.
Airflow Direction: Air intake from front, air exhaustion from rear (front-to-rear).

Port Details

10GE SFP+ Ports: 24 ports supporting various optical modules and cables, including Оптический модуль GEs, 10GE SFP+ optical modules, and high-speed copper cables.
40GE QSFP+ Ports: 6 ports compatible with QSFP+ оптический модульs and high-speed copper cables. Note: A QSFP+ optical port cannot be split into four 10GE ports.

Мощность и охлаждение

The S6730-S24X6Q supports dual hot-swappable power modules, allowing for AC and DC inputs:
AC Input: 100 V AC to 240 V AC, 50/60 Hz.
High-Voltage DC Input: 240 V DC.
DC Input: -48 V DC to -60 V DC.
Maximum Power Consumption: 249 W.
Typical Power Consumption: 135 W.
Fan Modules: Four pluggable fan modules with front-to-rear airflow design for efficient cooling.

Stacking and Virtualization

The switch supports stacking through its 10GE SFP+ and 40GE QSFP+ ports, allowing multiple switches to function as a single logical unit for simplified management and enhanced scalability. It also supports VXLAN L2 and L3 gateways, enabling network virtualization for flexible and efficient network designs.


Элементы системы безопасности

The S6730-S24X6Q offers comprehensive security features to protect network integrity:
Access Control Lists (ACLs): Permit or deny traffic based on predefined security policies.
802.1X Authentication: Ensures that only authorized users can access the network.
DHCP Snooping: Prevents unauthorized DHCP servers from distributing IP addresses.
IP Source Guard: Blocks packets with spoofed IP addresses.
Dynamic ARP Inspection (DAI): Protects against ARP spoofing attacks.

Quality of Service (QoS)

The switch provides advanced QoS features to ensure optimal performance for critical applications:
Traffic Classification: Identifies and classifies incoming traffic based on various parameters.
Traffic Policing and Shaping: Controls the rate of traffic sent or received on a network interface.
Priority Queuing: Ensures that high-priority traffic is transmitted first.
Congestion Management: Implements mechanisms to prevent and manage network congestion.

Управление и техническое обслуживание

The S6730-S24X6Q supports various management methods for ease of use:
Command-Line Interface (CLI): Provides a text-based interface for configuration and monitoring.
Web-Based Management: Без учета стоимостиers a graphical user interface accessible through web browsers.


Huawei CloudEngine S6730-S24X6Q Switches

Huawei All Серия документов Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected])



S6730-S24X6Q (02353AJW/02353AJW-001/02353AJW-003/02353AJW-004)

Version Mapping

Table 4-227 lists the mapping between the S6730-S24X6Q chassis and software versions.

Table 4-227 Version mapping

Series

Модель (модель)

Версия для ЭВМ

S6730-S

S6730-S24X6Q

02353AJW: V200R019C00 and later versions

02353AJW-001: V200R020C10 and later versions

02353AJW-003: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02353AJW-004: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

Примечание:

V200R021C01 is not supported.

Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command (supported in V200R021C00 and later versions) to check the software versions supported by the device before performing a downgrade.

Appearance and Structure

Figure 4-94 S6730-S24X6Q appearance

1

24 10GE SFP+ порта

Применимые модули и кабели:
  • GE optical module

  • Оптический модуль GE-CWDM

  • Оптический модуль GE-DWDM

  • Модуль GE copper

  • 10GE SFP+ оптический модуль (OSXD22N00 не поддерживается)

  • 10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)

  • 10GE-CWDM оптический модуль

  • 10GE-DWDM оптический модуль

  • 1 м, 3 м, 5 м и 10 м SFP+ высокоскоростные медные кабели

  • Кабели SFP+ AOC длиной 3 м и 10 м

  • Выделенные кабели SFP+ 0,5 м и 1,5 м (поддерживаются последними 16 портами SFP+ и используются только для штабелирования с нулевой конфигурацией)

2

Шесть оптических портов 40GE QSFP+

Применимые модули и кабели:
  • QSFP+ optical module

  • 1 м, 3 м и 5 м от QSFP+ до QSFP+ высокоскоростные медные кабели

  • Кабель QSFP+ - QSFP+ AOC длиной 10 м

  • 2 m QSFP28 выделенный стековой кабель (поддерживается в V200R020C10 и более поздних версиях)

  • QSFP28 optical module (supported in V200R024C00 and later versions, need a license loaded)

  • 1 m QSFP28 to QSFP28 high-speed copper cable (supported in V200R024C00 and later versions, need a license loaded)

  • 10 m QSFP28 to QSFP28 AOC cable (supported in V200R024C00 and later versions, need a license loaded)

Примечание:

A QSFP+ optical port cannot be split into four 10GE ports.

In V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit/s.

The QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ В одно и то же время slot-id | all ] command, and restart the switch.

3

Наземный винт

Примечание:
It is used with a ground cable.

4

Слот для карт SSD

Примечание:

This slot is reserved for future use.

5

Один консольный порт

6

Один управленческий порт эт

7

Один USB-интерфейс порт

8

Одна кнопка PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

Слот для модуля вентилятора 1

Примечание:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

10

Слот для модуля вентилятора 2

Примечание:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

11

Слот для модуля вентилятора 3

Примечание:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

12

Слот для модуля вентилятора 4

Примечание:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

13

Слот модуля питания 1

Примечание:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

14

Слот модуля питания 2

Примечание:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

Port 3. Описание

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-228 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-228 Attributes of a 10GE SFP+ port

Attribute

3. Описание

Тип коннектора

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Режим работы

GE/10GE auto-sensing

40GE QSFP+ optical port

A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s. Table 4-229 describes the attributes of a QSFP+ optical port.
Table 4-229 Attributes of a QSFP+ optical port

Attribute

3. Описание

Тип коннектора

MPO/LC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ba

Консольный порт (port)

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-230.
Table 4-230 Attributes of a console port

Attribute

3. Описание

Тип коннектора

Код Код RJ45

Standards compliance

Рс -232

Режим работы

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Управление портом ETH

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-231 describes the attributes of an ETH management port.
Table 4-231 Attributes of an ETH management port

Attribute

3. Описание

Тип коннектора

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 м.

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration.

USB-порт

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Показатель для оценки работы 3. Описание

Figure 4-95 Indicators on the S6730-S24X6Q
Table 4-232 Description of indicators on the switch

- нет. Нет.

Indicator

Имя и фамилия

Цвет (Color)

1. Статус

Description

1

Система управленческой информации

Показатель состояния системы

-

Без учета стоимости

Система не работает.

- зеленый цвет

Быстро моргая,

Система начинает работать.

- зеленый цвет

- вот так.

На этапе подготовки к запуску системы индикатор SYS является устойчивым зеленым и длится не более 30 секунд.

- зеленый цвет

Медленно моргая,

Система работает нормально.

- красный цвет

- вот так.

После регистрации система, как правило, не работает, либо сигнализация вентилятора или сигнализация температуры была создана.

2

MST (англ.)

Индикатор стека

-

Без учета стоимости

Переключатель не является главным переключателем в стеке.

- зеленый цвет

- я моргаю.

Переключатель-это главный переключатель в стеке или автономный переключатель.

3

Имя и фамилия

Идентификатор индикатора

-

Без учета стоимости

Идентификатор не используется (состояние по умолчанию).

Цвет: синий

- вот так.

Индикатор определяет переключатель для обслуживания. Идентификатор может быть включен или выключен удаленно, чтобы помочь инженерам на местах найти переключатель для обслуживания.

4

-

Service port indicator (10GE optical port)

Примечание:

Каждый оптический порт имеет два одноцветных индикатора. Слева-индикатор ACT (желтый), справа-индикатор LINK (зеленый).

Стрелы показывают позиции портов. Нижняя стрелка указывает на порт внизу, а верхняя стрелка указывает на порт наверху.

-

Без учета стоимости

Порт не подключен или был закрыт.

- зеленый цвет

- вот так.

Была установлена связь с портом.

-

Без учета стоимости

Порт не отправляет и не принимает данные.

- желтый цвет

- я моргаю.

Порт отправляет или принимает данные.

5

-

Service port indicator (40GE optical port)

Примечание:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

-

Без учета стоимости

Порт не подключен или был закрыт.

- зеленый цвет

- вот так.

Была установлена связь с портом.

- я моргаю.

Порт отправляет или принимает данные.

6

Л/о

Индикатор порта ETH

-

Off

Порт эт не связан.

- зеленый цвет

- вот так.

Соединение с портом ETH.

- зеленый цвет

- я моргаю.

Порт Eth отправляет или принимает данные.

7

USB

Показатель развертывания на базе США

-

Off

  • Нет USB флэш-накопитель подключен к выключателю.

  • USB порт поврежден.

  • Индикатор поврежден.

  • USB flash drive не имеет никакого файла конфигурации и не может быть использован для развертывания.

  • Переключатель был обновлен с помощью USB flash drive и перезапускается.

- зеленый цвет

- вот так.

Развертывание на базе США завершено.

- зеленый цвет

- я моргаю.

Система считывает данные с USB флэш-накопителя.

- желтый цвет

- вот так.

Переключатель скопировал все необходимые файлы и завершил проверку файлов. USB flash drive может быть удален из переключателя.

- красный цвет

- я моргаю.

При выполнении конфигурационного файла или чтении данных с USB-накопителя произошла ошибка.

Power Supply Configuration

Терез 88pl99ace1switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Рассеивание тепла

Терез 88pl99ace1S6730-S24X6Q uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Технические характеристики

Table 4-233 lists technical specifications of the S6730-S24X6Q.

Table 4-233 Technical specifications

Пункт повестки дня

Description

Память (RAM)

4 гб

3. Вспышка

2 гб в общей сложности. Чтобы просмотреть размер доступной флэш-памяти, запустите the Версия для отображенияRe88pl99ace1command.

Среднее время между неисправностями (MTBF)

62,27 года

Среднее время ремонта (MTTR)

2 часа

Наличие свободных мест

> > 0.99999 (к)

Защита от резкого увеличения нагрузки в портах обслуживания

N/A

Защита от перегрузки электропитания

  • Использование модулей питания переменного тока: ±6 kV в дифференциальном режиме, ±6 kV в общем режиме

  • Использование модулей постоянного тока: ±2 kV в дифференциальном режиме, ±4 kV в общем режиме

Dimensions (H x W x D)

  • Основные размеры (за исключением частей, выступающих из кузова): 43,6 мм x 442,0 мм x 420,0 мм (1,72 дюйма). X 17,4 дюйма. X 16,5 дюйма.

  • Максимальные размеры (глубина-расстояние от портов на передней панели до ручки на задней панели): 43,6 мм x 442,0 мм x 446,0 мм (1,72 дюйма). X 17,4 дюйма. X 17,6 дюйма.

Weight (with packaging)

8.9 kg (19.62 lb)

Порты стека

  • Любые 10GE SFP+ порты (максимум 16 физических портов)

  • Любые 40GE QSFP+ порты (максимум 6 физических портов)

РТС (RTC)

Поддержка со стороны

Категория < < р > >

Поддержка не оказывалась

По (фр.)

Поддержка не оказывалась

Диапазон номинального напряжения

  • Переменный вход: от 100 в переменного тока до 240 в переменного тока, 50/60 гц

  • Напряжение постоянного тока: 240 в постоянного тока

  • Вход постоянного тока: -48 в постоянного тока до -60 в постоянного тока

Диапазон максимального напряжения

  • AC вход: 90 в переменного тока до 290 в переменного тока, 45 гц до 65 гц

  • Напряжение постоянного тока: от 190 в постоянного тока до 290 в постоянного тока

  • Вход постоянного тока: - 38,4 в постоянного тока до -72 в постоянного тока

Максимальная потребляемая мощность

High temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W

Типичное потребление энергии

30% traffic under the ATIS standard and dual power modules: 135 W

Рабочая температура

-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Примечание:

Когда высота составляет 1800-5000 м (5906-16404 футов), самая высокая рабочая температура уменьшается на 1 градус (1,8 градуса) каждый раз, когда высота увеличивается на 220 м (722 футов).

Выключатель не может быть запущен, когда температура окружающей среды ниже 0°C (32°F).

Температура при хранении

От 40 до +70 (от 40 до +158)

Шум при нормальной температуре (27°C, звуковая мощность)

< 65 дб (A)

Относительная влажность воздуха

5% to 95%, noncondensing

Рабочая высота над уровнем моря

0-5000 м (0-16404 футов)

3. Сертификация

  • Сертификация емс

  • Сертификация в области безопасности

  • Сертификация производства

Номер части

02353AJW

02353AJW-001

02353AJW-003

02353AJW-004


tag-icon Горячие метки: Huawei переключается

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.